Code of Ordinances

Share & Bookmark, Press Enter to show all options, press Tab go to next option
Print

 Code of Ordinances

By clicking the link below, you will be able to search the complete set of Parish Ordinances. Code Enforcement for Property Standards is responsible for enforcing the Parish Ordinances relating to health and safety, property maintenance standards, condemnation of unsafe structures and zoning compliance.

Click here to search Parish Ordinances.

PROPOSED ORDINANCE AMENDMENTS

FLOODPLAIN MANAGEMENT

ORDINANCE AMENDMENT TIMELINE

October 21, 2025          Planning & Zoning Board Meeting

·      Introduction & Comment Period

·      Public comment period ensues

·      Draft ordinance amendments posted to CPPJ Website & social media outlets

November 18, 2025      Planning & Zoning Board Meeting

·      Public hearing, final action and recommendation to the Police Jury

November 20, 2025      Police Jury Meeting

·      Final Action

FLOODPLAIN MANAGEMENT ORDINANCE REV. 9-2025

 

Chapter 26, Article IX, Section 26-330 (a) (10):

 

(10) New construction and substantial improvements, with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria:

a.  A minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding shall be provided.

b. The bottom of all openings shall be no higher than one (1) foot above grade.

c.  Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters.

 

CFR 44 §60.3

Require, for all new construction and substantial improvements, that fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters.

To request a certified Ordinance or Resolution, or for general questions, please contact the Records Department at (337) 721-3500.